Zodiac Uranus 35 Heat Exchanger with Housing
High-performance titanium plate heat exchanger.
Includes digital control.
Compatible with all domestic heating systems (heat pump, boiler, geothermal, and solar), even at low temperatures.
Model with housing.
Equipment
Heating circuit connection (primary):
With insulated pipes.
Equipped with a safety valve (pressure set at 3 bar) and a suitably sized expansion tank.
Pool circuit connection (secondary):
With PVC pipes of at least Ø50.
Mandatory by means of a bypass.
Class A low-consumption circulation pump.
Pre-assembled 2.5 m power cable and plug.
Thermostat with LCD display.
Flow switch.
230 V single-phase cable with plug.
Drain plug.
UP 35 Models
Useful power at 45°C: 13 kW
Useful power at 90°C: 35 kW
Primary water flow rate: 1.5 m3/h
Secondary water flow rate: 1.5 m3/h
Hydraulic connection
Primary 26/34 Ø
Secondary PVC 50 Ø
Primary 32/42 Ø
Secondary PVC 50 Ø
Dimensions (W x D x H): 28.5 x 36.5 x 76
Weight: 37 kg